Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
World Neurosurg ; 171: 148-151, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2264987

ABSTRACT

BACKGROUND: Morbid obesity can pose unique challenges in the endovascular treatment of cerebrovascular diseases, particularly in the management of ruptured aneurysms. CASE DESCRIPTION: This technical report discusses the challenges faced during the treatment of a ruptured aneurysm in a morbidly obese patient with a body mass index of 101. The technical adaptations used included the utilization of Dyna CT for routine imaging, vacuum assist devices for patient transfer, and a transradial approach to avoid groin complications. The technical adaptations used in the management of the ruptured aneurysm in the morbidly obese patient were effective in overcoming the challenges posed by the patient's obesity. CONCLUSION: This technical report and literature review can serve as a guide for physicians treating morbidly obese patients with cerebrovascular diseases. Utilization of advanced technology and innovative approaches can aid in overcoming the challenges posed by obesity and improving patient outcomes.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Obesity, Morbid , Humans , Intracranial Aneurysm/therapy , Treatment Outcome , Body Mass Index , Obesity, Morbid/complications , Aneurysm, Ruptured/complications , Embolization, Therapeutic/methods , Endovascular Procedures/methods
3.
Acta Neurochir (Wien) ; 164(8): 2191-2202, 2022 08.
Article in English | MEDLINE | ID: covidwho-1844388

ABSTRACT

OBJECTIVE: Peri-ophthalmic aneurysm is a special type of aneurysm. We assessed the relationship between ophthalmic artery (OA) origin and aneurysm and examined the effect of a pipeline embolization device (PED, Covidien/Medtronic) with or without coils on aneurysm occlusion rate and visual outcomes. METHODS: We retrospectively analyzed 194 peri-ophthalmic aneurysms in 189 patients among 1171 patients treated with a PED in a Chinese post-market multi-center registry study from November 2014 to October 2019. Peri-ophthalmic aneurysms were defined as carotid-ophthalmic segment aneurysms arising from the internal carotid artery dorsal wall at, or distal to, the OA origin, with a superior or superomedial projection. The relationship between OA origin and the aneurysm was classified as follows: type A, OA originating separate from the aneurysm; type B, OA originating from the aneurysm neck or dome. Patients with aneurysm were divided into the PED-only group and the PED + coils group according to treatment. RESULTS: The median follow-up time was 6.8 months (range, 5.3-20.2 months). There were 163 occluded aneurysms (84%) and 31 aneurysms with incomplete occlusion (16%). A multivariate analysis showed that type B aneurysm was a risk factor for incomplete occlusion in the PED-only group (odds ratio [OR] 4.854, 95% confidence interval [CI] 1.878-12.548, P = 0.001). Visual symptoms at final follow-up correlated with preoperative visual symptoms (OR 22.777, 95% CI 3.115-166.555, P = 0.002). CONCLUSIONS: Type B aneurysm is associated with a lower occlusion rate after PED-only treatment. Patients with preoperative visual symptoms should be treated promptly to avoid permanent visual symptoms.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Cohort Studies , Embolization, Therapeutic/adverse effects , Humans , Intracranial Aneurysm/surgery , Intracranial Aneurysm/therapy , Retrospective Studies , Treatment Outcome
4.
Neurosurgery ; 90(6): 700-707, 2022 06 01.
Article in English | MEDLINE | ID: covidwho-1759804

ABSTRACT

BACKGROUND: The pipeline embolization device (PED; ev3/Covidien) has proven safe and effective for treating selected intracranial aneurysms. This device's versatility and popularity have driven increased interest in expanding the latest 2018 Food and Drug Administration-approved indications. OBJECTIVE: To compare "off-label" and "on-label" PED treatment. METHODS: Retrospective analysis of aneurysms treated with PED at a single center from 2013 to 2019. Comparisons were made based on the 2018 Food and Drug Administration-approved indications. RESULTS: A total of 492 treated aneurysms were included (65.2% on-label and 34.8% off-label). Aneurysm complete and near-complete occlusion rate was nonsignificantly lower in the off-label group (80.9% vs 85.7%; P = .19). Off-label treatment had higher rate of poor functional outcomes (modified Rankin Scale [mRS] >2: 10.3% vs 3.5%; P = .002). Although pretreatment mRS was already higher in the off-label group (5.3% vs 0.3%; P < .001) and there were no differences in mRS worsening during follow-up (5.5% vs 2.9%; P = .15). We also found a trend to a higher rate of intracranial hemorrhagic complications in the off-label group (4.7% vs 1.6%; P = .05), but there were no differences in hemorrhages requiring surgical intervention (1.8% vs 1.3%; P = .65). There were no differences in retreatment, thromboembolic complications, and mortality rates. CONCLUSION: Off-label PED treatment may be considered for select aneurysms, which are challenging to treat with other techniques. These cases have similar complete and near-complete occlusion rates compared with on-label cases. There are, however, higher risks of poor functional outcomes despite similar rates of thromboembolic and hemorrhagic complications. This is partly explained by the significantly higher pretreatment mRS score in the off-label group.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Thromboembolism , Embolization, Therapeutic/methods , Follow-Up Studies , Humans , Intracranial Aneurysm/therapy , Off-Label Use , Retrospective Studies , Thromboembolism/therapy , Treatment Outcome , United States , United States Food and Drug Administration
5.
PLoS One ; 15(6): e0233981, 2020.
Article in English | MEDLINE | ID: covidwho-1456053

ABSTRACT

We aimed to examine aneurysm hemodynamics with intra-saccular pressure measurement, and compare the effects of coiling, stenting and stent-assisted coiling in proximal segments of intracranial circulation. A cohort of 45 patients underwent elective endovascular coil embolization (with or without stent) for intracranial aneurysm at our department. Arterial pressure transducer was used for all measurements. It was attached to proximal end of the microcatheter. Measurements were taken in the parent artery before and after embolization, at the aneurysm dome before embolization, after stent implantation, and after embolization. Stent-assisted coiling was performed with 4 different stents: LVIS and LVIS Jr (Microvention, Tustin, CA, USA), Leo (Balt, Montmorency, France), Barrel VRD (Medtronic/ Covidien, Irvine, CA, USA). Presence of the stent showed significant reverse correlation with intra-aneurysmal pressure-both systolic and diastolic-after its implantation (r = -0.70 and r = -0.75, respectively), which was further supported by correlations with stent cell size-r = 0.72 and r = 0.71, respectively (P<0.05). Stent implantation resulted in significant decrease in diastolic intra-aneurysmal pressure (p = 0.046). Systolic or mean intra-aneurysmal pressure did not differ significantly. Embolization did not significantly change the intra-aneurysmal pressure in matched pairs, regardless of the use of stent (p>0.05). In conclusion, low-profile braided stents show a potential to divert blood flow, there was significant decrease in diastolic pressure after stent placement. Flow-diverting properties were related to stent porosity. Coiling does not significantly change the intra-aneurysmal pressure, regardless of packing density.


Subject(s)
Blood Pressure , Intracranial Aneurysm/physiopathology , Stents , Aged , Arterial Pressure , Blood Circulation , Blood Vessel Prosthesis , Brain/blood supply , Brain/physiopathology , Embolization, Therapeutic , Female , Hemodynamics , Humans , Intracranial Aneurysm/therapy , Male , Middle Aged
6.
Interv Neuroradiol ; 26(5): 557-565, 2020 Oct.
Article in English | MEDLINE | ID: covidwho-1455862

ABSTRACT

BACKGROUND: The Low-profile Visualized Intraluminal Support device (LVIS) has been successfully used to treat cerebral aneurysm, and the push-pull technique has been used clinically to compact the stent across aneurysm orifice. Our aim was to exhibit the hemodynamic effect of the compacted LVIS stent. METHODS: Two patient-specific aneurysm models were constructed from three-dimensional angiographic images. The uniform LVIS stent, compacted LVIS and Pipeline Embolization Device (PED) with or without coil embolization were virtually deployed into aneurysm models to perform hemodynamic analysis. Intra-aneurysmal flow parameters were calculated to assess hemodynamic differences among different models. RESULTS: The compacted LVIS had the highest metal coverage across the aneurysm orifice (case 1, 46.37%; case 2, 67.01%). However, the PED achieved the highest pore density (case 1, 19.56 pores/mm2; case 2, 18.07 pores/mm2). The compacted LVIS produced a much higher intra-aneurysmal flow reduction than the uniform LVIS. The PED showed a higher intra-aneurysmal flow reduction than the compacted LVIS in case 1, but the results were comparable in case 2. After stent placement, the intra-aneurysmal flow was further reduced as subsequent coil embolization. The compacted LVIS stent with coils produced a similar reduction in intra-aneurysmal flow to that of the PED. CONCLUSIONS: The combined characteristics of stent metal coverage and pore density should be considered when assessing the flow diversion effects of stents. More intra-aneurysmal flow reductions could be introduced by compacted LVIS stent than the uniform one. Compared with PED, compacted LVIS stent may exhibit a flow-diverting effect comparable to that of the PED.


Subject(s)
Embolization, Therapeutic/methods , Intracranial Aneurysm/therapy , Stents , Subarachnoid Hemorrhage/therapy , Angiography, Digital Subtraction , Cerebral Angiography , Computer Simulation , Hemodynamics , Humans , Hydrodynamics , Imaging, Three-Dimensional , Intracranial Aneurysm/diagnostic imaging , Magnetic Resonance Angiography , Prosthesis Design , Subarachnoid Hemorrhage/diagnostic imaging
7.
Neurosurgery ; 87(3): 516-522, 2020 09 01.
Article in English | MEDLINE | ID: covidwho-1455333

ABSTRACT

BACKGROUND: Pipeline embolization device (PED; Medtronic) and stent-assisted coiling (SAC) are established modalities for treatment of intracranial aneurysms. OBJECTIVE: To comparatively assess the efficacy of these techniques. METHODS: We conducted a retrospective analysis of patients with aneurysms treated at our institution with either PED from 2013 to 2017 or SAC from 2009 to 2015. All large (>10 mm), ruptured, fusiform, anterior communicating artery, posterior circulation aneurysms, and patients with no available follow-up imaging were eliminated before running the propensity score matching (PSM). Patients were matched using nearest neighbor controlling for: age, gender, smoking, exact location, maximal diameter, and presence of multiple aneurysms. Total hospital costs for equipment and implants were calculated from procedure product and hospital billing records, and compared between the propensity-matched pairs. RESULTS: Out of 165 patients harboring 202 aneurysms; 170 (84.2%) were treated with the PED, and 32 (15.8%) were treated using SAC. PSM resulted in 23 matched pairs; with significantly longer follow up in the SAC group (mean 29.8 vs 14.1 mo; P = .0002). Complete occlusion rates were not different (82.6 vs 87%; P = .68), with no difference between the groups for modified Rankin Scale on last clinical follow-up, procedural complications or retreatment rates. Average total costs calculated from the hospital records, including equipment and implants, were not different between propensity-score matched pairs (P = .48). CONCLUSION: PED placement and SAC offer equally efficacious occlusion rates, functional outcomes, procedural complication rates, and cost profiles for small unruptured anterior circulation saccular aneurysms which do not involve the anterior communicating artery.


Subject(s)
Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Stents , Adult , Aged , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Female , Humans , Male , Middle Aged , Propensity Score , Retrospective Studies , Treatment Outcome
9.
Clin Neurol Neurosurg ; 209: 106931, 2021 10.
Article in English | MEDLINE | ID: covidwho-1385293

ABSTRACT

OBJECTIVES: The collateral effect of the COVID-19 pandemic on interventional stroke care is not well described. We studied this effect by utilizing stroke device sales data as markers of interventional stroke case volume in the United States. METHODS: Using a real-time healthcare device sales registry, this observational study examined trends in the sales of thrombectomy devices and cerebral aneurysm coiling from the same 945 reporting hospitals in the U.S. between January 22 and June 31, 2020, and for the same months in 2018 and 2019 to allow for comparison. We simultaneously reviewed daily reports of new COVID-19 cases. The strength of association between the cumulative incidence of COVID-19 and procedural device sales was measured using Spearman rank correlation coefficient (CC). RESULTS: Device sales decreased for thrombectomy (- 3.7%) and cerebral aneurysm coiling (- 8.5%) when comparing 2019-2020. In 2020, thrombectomy device sales were negatively associated with the cumulative incidence of COVID-19 (CC - 0.56, p < 0.0001), with stronger negative correlation during April (CC - 0.97, p < 0.0001). The same negative correlation was observed with aneurysm treatment devices (CC - 0.60, p < 0.001), with stronger correlation in April (CC - 0.97, p < 0.0001). CONCLUSIONS: The decline in sales of stroke interventional equipment underscores a decline in associated case volumes. Future pandemic responses should consider strategies to mitigate such negative collateral effects.


Subject(s)
COVID-19/epidemiology , Commerce/trends , Stroke/epidemiology , Thrombectomy/trends , Vascular Access Devices/trends , COVID-19/prevention & control , Humans , Intracranial Aneurysm/epidemiology , Intracranial Aneurysm/therapy , Pandemics , Stroke/therapy , Thrombectomy/economics , United States/epidemiology , Vascular Access Devices/economics
10.
Stroke Vasc Neurol ; 6(4): 542-552, 2021 12.
Article in English | MEDLINE | ID: covidwho-1153702

ABSTRACT

BACKGROUND: During the COVID-19 pandemic, decreased volumes of stroke admissions and mechanical thrombectomy were reported. The study's objective was to examine whether subarachnoid haemorrhage (SAH) hospitalisations and ruptured aneurysm coiling interventions demonstrated similar declines. METHODS: We conducted a cross-sectional, retrospective, observational study across 6 continents, 37 countries and 140 comprehensive stroke centres. Patients with the diagnosis of SAH, aneurysmal SAH, ruptured aneurysm coiling interventions and COVID-19 were identified by prospective aneurysm databases or by International Classification of Diseases, 10th Revision, codes. The 3-month cumulative volume, monthly volumes for SAH hospitalisations and ruptured aneurysm coiling procedures were compared for the period before (1 year and immediately before) and during the pandemic, defined as 1 March-31 May 2020. The prior 1-year control period (1 March-31 May 2019) was obtained to account for seasonal variation. FINDINGS: There was a significant decline in SAH hospitalisations, with 2044 admissions in the 3 months immediately before and 1585 admissions during the pandemic, representing a relative decline of 22.5% (95% CI -24.3% to -20.7%, p<0.0001). Embolisation of ruptured aneurysms declined with 1170-1035 procedures, respectively, representing an 11.5% (95%CI -13.5% to -9.8%, p=0.002) relative drop. Subgroup analysis was noted for aneurysmal SAH hospitalisation decline from 834 to 626 hospitalisations, a 24.9% relative decline (95% CI -28.0% to -22.1%, p<0.0001). A relative increase in ruptured aneurysm coiling was noted in low coiling volume hospitals of 41.1% (95% CI 32.3% to 50.6%, p=0.008) despite a decrease in SAH admissions in this tertile. INTERPRETATION: There was a relative decrease in the volume of SAH hospitalisations, aneurysmal SAH hospitalisations and ruptured aneurysm embolisations during the COVID-19 pandemic. These findings in SAH are consistent with a decrease in other emergencies, such as stroke and myocardial infarction.


Subject(s)
COVID-19 , Intracranial Aneurysm , Subarachnoid Hemorrhage , Cross-Sectional Studies , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/epidemiology , Intracranial Aneurysm/therapy , Pandemics , Prospective Studies , Retrospective Studies , SARS-CoV-2 , Subarachnoid Hemorrhage/diagnostic imaging , Subarachnoid Hemorrhage/epidemiology , Treatment Outcome
11.
J Stroke Cerebrovasc Dis ; 30(2): 105429, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-899244

ABSTRACT

The current Coronavirus pandemic due to the novel SARS-Cov-2 virus has proven to have systemic and multi-organ involvement with high acuity neurological conditions including acute ischemic strokes. We present a case series of consecutive COVID-19 patients with cerebrovascular disease treated at our institution including 3 cases of cerebral artery dissection including subarachnoid hemorrhage. Knowledge of the varied presentations including dissections will help treating clinicians at the bedside monitor and manage these complications preemptively.


Subject(s)
Aortic Dissection/mortality , COVID-19/mortality , Hemorrhagic Stroke/mortality , Hospital Mortality , Intensive Care Units , Intracranial Aneurysm/mortality , Ischemic Stroke/mortality , Patient Admission , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnosis , Aortic Dissection/therapy , COVID-19/diagnosis , COVID-19/therapy , Female , Hemorrhagic Stroke/diagnosis , Hemorrhagic Stroke/therapy , Humans , Intracranial Aneurysm/diagnosis , Intracranial Aneurysm/therapy , Ischemic Stroke/diagnosis , Ischemic Stroke/therapy , Male , Middle Aged , New York City/epidemiology , Prospective Studies , Risk Assessment , Risk Factors
12.
BMJ Case Rep ; 13(10)2020 Oct 04.
Article in English | MEDLINE | ID: covidwho-814252

ABSTRACT

This is a report of the first three cases of endovascular aneurysm treatment that were proctored by a remote interventionalist using a novel high-resolution low-latency streaming technology. The proctor was located in a neurovascular centre and supported the treating interventional teams in two distant cities (up to 800 km/500 miles apart). All aneurysms were treated using the Woven EndoBridge (WEB) embolisation system, either electively or following subarachnoid haemorrhage. On-site proctoring was not possible due to travel restrictions during the COVID-19 pandemic. WEB placement was feasible in all cases. Good rapport between proctors and treating physicians was reported, enabled by the high-resolution image transmission and uninterrupted feedback/discussion via audiostream. No clinical complications were encountered. Short-term follow-up revealed adequate occlusion of all treated aneurysms. The employed streaming technology provided effective remote proctoring during complex aneurysm cases, including the management of technical complications.


Subject(s)
Betacoronavirus , Coronavirus Infections/prevention & control , Endovascular Procedures/methods , Intracranial Aneurysm/therapy , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Telemedicine/methods , Angiography, Digital Subtraction/methods , COVID-19 , Humans , Intracranial Aneurysm/diagnostic imaging , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL